Specs at a glance
-
Input
1 x analogue 4...20 mA
-
Output
1 x open collector
-
Display
LCD 26 mm (1.02")
5-digit
Bargraph
Plain text display -
Power Supply
Loop powered
Field of application
The indicator shows the measured signal on the large, backlit display. A bar graph indicates the value graphically for a quick process overview. An editable plain text field displays further information like engineering unit or TAG. Limit value infringement is also signalized and an open collector can be switched. The indicator is powered directly from the 4...20 mA loop and doesn't need a separate power supply. For applications in hazardous areas the device is available with Ex approvals.
Microcontroller controlled process indicator with field housing and illuminated LC display. The measuring range, decimal point and offset of the display can be configured comfortably by means of three keys in the device with the housing open or by means of a PC with the FieldCare PC software.
Benefits
Display of 4 to 20 mA measured values
5-digit measured value display with dimension, bar graph and backlight
No external power supply required
Versions: Fiber glass reinforced plastic respectively aluminum for Ex-applications
Easy 3-key operation; or configuration with FieldCare PC software; or configuration without power supply using setup box
International approvals; marine approval
Allows the HART® transmission protocol to pass unimpeded
Fundamental selection
-
Simple products
- Easy to select, install and operate
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
TI RIA16
Loop-powered field indicator
EN 13/02/202307/11/201625/04/201427/09/201328/03/2013Language:
English
Version:
13/02/2023
File size:
687.5 KB
File name:
TI00144REN_0623-00.pdf
-
-
-
Operating Instruction (BA)
BA RIA16
Loop-powered field indicator
EN 31/01/202325/04/201427/09/201308/04/201308/11/2012Language:
English
Version:
31/01/2023
File size:
2.1 MB
File name:
BA00280REN_0623-00.pdf
-
-
-
Short Instruction (KA)
KA RIA16
Loop-powered field indicator
EN 01/03/202321/04/201704/11/201426/06/201316/05/2011Language:
English
Version:
01/03/2023
File size:
1.6 MB
File name:
KA00279REN_0523-00.pdf
-
-
-
Ex Safety Instruction (XA)
RIA16
FM:
Control Drawing IS, NI, DIP
120500111Language:
English
Version:
04/03/2014
File size:
1.4 MB
File name:
120500111.pdf
-
-
-
Ex Safety Instruction (XA)
RIA14, RIA16
Field Indicator
Ex ib IIC T4...T6 Gb
Ex db IIC T4...T6 GbEN 26/12/202228/09/202214/09/2020Language:
English
Version:
26/12/2022
File size:
548.9 KB
File name:
XA02237KEN_0322-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA RIA14, RIA16
1 Ex ib [ia] IIC T6...T4 Gb
EN 07/08/202423/03/202003/03/2017Language:
English
Version:
07/08/2024
File size:
448.2 KB
File name:
XA01462KEN_0324-00.pdf
-
-
-
Ex Safety Instruction (XA)
RIA16
ATEX, IECEx: Ex ib [ia Ga] IIC T6 Gb
Safety instructions for electrical apparatus in explosion-hazardous
areasEN 18/07/202205/08/201609/10/2009Language:
English
Version:
18/07/2022
File size:
384.1 KB
File name:
XA00088REN_1422-00.pdf
-
-
-
Ex Safety Instruction (XA)
RIA16
CSA:
Control Drawing IS, NI, DIP
120500112Language:
English
Version:
08/12/2008
File size:
80.8 KB
File name:
120500112.pdf
-
-
-
Certificates FM/CSA (ZD)
Control Drawing FM IS/NI/DIP RID16
FOUNDATION Fieldbus Field Indicator RID16
Installation Notes for Hazardous LocationsLanguage:
English
Version:
31/03/2010
File size:
130.6 KB
File name:
120600111.pdf
-
-
-
Certificates FM/CSA (ZD)
Control Drawing FM XP, NI RIA16
Loop Powered Field Display RIA16
Installation Notes for hazardous locationsEN 02/06/201408/04/2010Language:
English
Version:
02/06/2014
File size:
128.8 KB
File name:
120500111.pdf
-